Ochratoxin (OTA) ELISA Test Kit

Analyte:Mycotoxin

Samples:liquid milk, milk powder, fermented milk,cheese, milk beverage

Specification
96 Test/Kit
Product introduction
Summary

Ochratoxin A (OTA) is a toxic metabolite produced by Aspergillus flavus and Penicillium genera. Ochratoxin A has a strong liver and kidney toxicity, and has teratogenic, mutagenic and carcinogenic.

OTA is the second important and harmful mycotoxin in the family following with Aflatoxin flavus. As the OTA producing fungi exist widely in nature, especially higher yield in cereals and cereals products, coffee, cocoa contaminated with OTA, it has been potential threat for human health and development of animal husbandry.



Intended Use

The Ochratoxin A ELISA Kit is an indirect competitive ELISA for the quantitative analysis of Ochratoxin A in grain, feed, etc.


Available Products

P/N              Sensitivity                Sample                                          
SC0015    0.15μg/kgCorn, wheat, compound feed, cattle fine feed, corn by-product 
SC00270.1μg/kgAlcohol, wine, beer, etc.


Precautions
1. Reagents should be brought to room temperature, 20–25ºC prior to use. Avoid prolonged (> 24 hours) storage at room temperature. 2. Immediately start the next step of operation after the washing procedure, avoid the microwell be dry affecting the detecting result. 3. Shake the reagent before use. 4. The Stop Solution is 2M sulphuric acid. Avoid contact with skin and mucous membranes. Immediately clean up any spills and wash area with copious amounts of water. If contact should occur, immediately flush with copious amounts of water. 5. Do not use reagents after expiration date. Do not substitute reagents from any other manufacturer into the test kit. Do not combine reagents from other Mycotoxin ELISA Kits with different Lot numbers. 6. The kit should be store at the temperature 2-8℃, do not freeze. Be sure to re-seal unused wells in the zip-lock bag with desiccant stored. Avoid directly exposure the reagents to light. 7. Any color conversion indicates that the reagent is deteriorated, please drop it. If the absorbance of negative control absorbance is less than 0.5, the reagent is probably deteriorated. 8. The incubating time is usually 15-20 minutes after dispensing Substrate A and 50µL Substrate B into the wells. If the color too less, please prolong the incubating time but should not exceed 30 minutes. Conversely, reduce the incubating time. 9. Crystallization of the Concentrated Wash buffer is a normal phenomenon, heat it before using. 10. The optimum reaction temperature is 25℃, too high or two low temperature would arise the change of the absorbance and sensitivity.